| Series | Example | System Version |
| IVSS | DHI-IVSS7008-1I | V2.004.0000000.2.R 2022-07-15 |
NB: The firmware version is based on the latest version when this document was created and may slightly differ from future versions, however, this will not affect any of the functionality.
Grub Entry
To enter Grub, press the * key continuously after powering on until the menu appears. There are currently three modes.
Normal Mode:
It is the default startup mode for the device, which starts Sonia normally.
Recovery Mode:
It is a debugging mode in which Sonia does not start and the serial port output is displayed on the VGA screen. This is useful for viewing device information and configuring the network. Drivers are not loaded in this mode, only the kernel is loaded for system debugging. The fixed password is 7ujMko0admin (unrelated to the admin password).
Rescue Mode:
This mode can restore the factory settings, open serial port output, and enable the sshd service.
Rescue Mode
Enter 1 and press Enter: restore the factory program. If there is an upgrade exception or other situation that prevents Normal Mode from starting up, this method can be used to restore the factory program.
Enter 2 and press Enter: clear the configuration partition. This is useful when you forget your password and need to clear the configuration.
Enter 3 and press Enter: open serial port output.
Enter 4 and press Enter: close serial port output. IVSS turns off serial port output by default.
Enter 5 and press Enter: enable sshd service.
Enter 6 and press Enter: disable sshd service.
Enter r and press Enter: reboot the system.
Comments